Installation&Operating InstructionsforSLIMZONEENVIRONMENTAL MODULE(SZEM)
which is connected to the ductwork by means of a coiled 8' (2.4m) length of 1/8" (3.2mm)PVC tubing. The length of the tubing provides protec
STEP DESCRIPTION DURATION6 Time delay – equalize system 30 seconds5 Self calibrate – 0 pressure 30 seconds4 Wait state – Status calibration Instantane
NOTE: The duration of each setup is approximate. Step 3 may repeat several times; whenthis happens the time will reset and count down to zero again.4.
TEMPERATURE PROBE INSTALLATIONDrill a 1/4" (4mm) hole into the ductwork at a recommended distance of 6" to 8" (15cm –20cm) downstream f
12high balance point will cause the SZP control module to disable the auxiliary heat source,and heating will be provided by the compressor only. An ou
WARRANTYLIMITED TWO YEAR WARRANTYThe manufacturer warrants to the original purchaser that its product and componentparts will be free from defects in
110-907 97255
TABLE OF CONTENTSIMPORTANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1INTROD
1IMPORTANTREAD THIS BOOKLET THOROUGHLY IN ORDER TOUNDERSTAND ALL THE OPERATION FEATURES OF YOURENVIRONMENTAL MODULE.RECORD THE SERIAL NUMBER IN THE SP
SLIMZONE ENVIRONMENTAL MODULE (SZEM)INTRODUCTIONThe Slimzone Environmental Module (SZEM) is an optional component in the SlimzonePremier system. The m
not be required. This is based on duct sizing where either zone is able to handle approximate-ly 75% of the total system CFM (cubic feet/minute). This
SZEM TERMINAL DESCRIPTIONSOutput terminals on the SZEM module are protected by current limiting devices which areactivated when the current draw excee
SETUPTRANSFORMERThe SZEM module requires a separate transformer rated at a minimum of 20 VA to powerthe module and the bypass actuator.LOCATIONCAUTION
6SZEM Wiring Diagram